DAKER DK PLUS
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
1
Active power (kW)
0,9
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
10
Dimensions H×W×D (mm)
440 × 88 (2U) × 405
Dimensions of battery cabinet HxWxD, mm
440 × 196 (4U) × 425
Net weight (kg)
16
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
2
Active power (kW)
1,8
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
10
Dimensions H×W×D (mm)
440 × 88 (2U) × 600
Dimensions of battery cabinet HxWxD, mm
440 × 88 (2U) × 600
Net weight (kg)
29,5
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
3
Active power (kW)
2,7
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
8
Dimensions H×W×D (mm)
440 × 88 (2U) × 600
Dimensions of battery cabinet HxWxD, mm
440 × 88 (2U) × 600
Net weight (kg)
30
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
5
Active power (kW)
5
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
5
Dimensions H×W×D (mm)
440 × 196 (4U) × 680
Dimensions of battery cabinet HxWxD, mm
–
Net weight (kg)
60
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
6
Active power (kW)
6
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
–
Dimensions H×W×D (mm)
440 × 88 (2U) × 680
Dimensions of battery cabinet HxWxD, mm
440 × 88 (2U) × 680
Net weight (kg)
25
Appointment
Office, server room, production
Number of phases
1
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
10
Active power (kW)
10
System
Transformable: rackmount or floor installation
Input voltage (V)
230 V, 1P + N
Input voltage range
176 V – 280 V at full load
Output voltage (V)
230 V ± 1%
Battery type
–
Dimensions H×W×D (mm)
440 × 132 (3U) × 680
Dimensions of battery cabinet HxWxD, mm
440 × 132 (3U) × 680
Net weight (kg)
26
Appointment
Office, server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
10
Active power (kW)
9
System
Transformable: rackmount or floor installation
Input voltage (V)
380 V, 3P + N
Input voltage range
305 V - 485 V
Output voltage (V)
230 V ± 1%
Battery type
–
Dimensions H×W×D (mm)
440 × 132 (3U) × 680
Dimensions of battery cabinet HxWxD, mm
440 × 132 (3U) × 680
Net weight (kg)
28
1 kVA
2 kVA
3 kVA
5 kVA
6 kVA
10 kVA
10 kVA
Bypass
Internal automatic
Back-feed protection
Yes
Emergency stop
Yes
Operating temperature / humidity
0 – 40 °C / from –20 to +80%
Protection index
IP21
View more details
SIMILAR MODELS
Any questions about the
DAKER DK PLUS?
Leave a request for consultation and we will get back to you as soon as possible.
Regarding the sale of Legrand equipment,
please contact the person:
KOVALKOV VASYL
CEO of S3 Energy Service
050 416 18 87
050 416 18 87
vasylstopper
© 2021 – All Rights Reserved
Mobile version
(044) 206-25-05
MON-FRI: 9 am - 6 pm
energy@c3.kiev.ua
Kyiv, Dragomanova 1D