archimod he
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
20
Active power (kW)
20
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
(or 220,230,240 1PH)
Input voltage range
400 V +15%/-20% 3PH –
230 V +15%/-20% 1PH
Output voltage (V)
380,400,415 3PH+N+PE
(or 220,230,240 1PH)
Height (mm)
2080
Width (mm)
517
Depth (mm)
912
Installable power modules
3
Installable battery modules
Up to 30
Net weight (kg)
205
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
40
Active power (kW)
40
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
(or 220,230,240 1PH)
Input voltage range
400 V +15%/-20% 3PH –
230 V +15%/-20% 1PH
Output voltage (V)
380,400,415 3PH+N+PE
(or 220,230,240 1PH)
Height (mm)
2080
Width (mm)
570
Depth (mm)
912
Installable power modules
6
Installable battery modules
Up to 24
Net weight (kg)
240
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
60
Active power (kW)
60
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
Input voltage range
400 V +15%/-20%
Output voltage (V)
380,400,415 3PH+N+PE
Height (mm)
2080
Width (mm)
570
Depth (mm)
912
Installable power modules
9
Installable battery modules
Up to 18
Net weight (kg)
276
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
100
Active power (kW)
100
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
Input voltage range
400 V +15%/-20%
Output voltage (V)
380,400,415 3PH+N+PE
Height (mm)
2080
Width (mm)
570
Depth (mm)
912
Installable power modules
15
Installable battery modules
–
Net weight (kg)
318
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
120
Active power (kW)
120
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
Input voltage range
400 V +15%/-20%
Output voltage (V)
380,400,415 3PH+N+PE
Height (mm)
2080
Width (mm)
570
Depth (mm)
912
Installable power modules
18
Installable battery modules
–
Net weight (kg)
364
Appointment
Server room, production
Number of phases
3
Technology
On-line double conversion VFI-SS-111
Nominal power (kVA)
80
Active power (kW)
80
Module power (kVA)
6.7 per power module
System
Modular, expandable and redundant UPS
Input voltage (V)
380,400,415 3PH+N+PE
Input voltage range
400 V +15%/-20%
Output voltage (V)
380,400,415 3PH+N+PE
Height (mm)
2080
Width (mm)
570
Depth (mm)
912
Installable power modules
12
Installable battery modules
–
Net weight (kg)
272
20 kVA
40 kVA
60 kVA
100 kVA
120 kVA
80 kVA
Bypass
Automatic and maintenance
Battery range type / UPS voltage
VRLA - AGM/252 VDC
Back-feed protection
N/C + N/O auxiliary contact
Emergency stop
Yes
Operating temp. / humidity
0 - 40°C / 0 - 95% non condensing
Protection index
IP21
View more details